CE , OIML, ISO standard
Model |
KEG-200(2gas) / KEG-500(4gas/5gas) |
|||
Measuring gas |
CO, HC, CO2, O2, Lamda(Air surplus rate), AFR, NOX (5gas) |
|||
Sensor Theory |
CO, HC, CO2, Non-Dispersive Infrared Analysis(NDIR) |
|||
CO |
HC |
CO2 |
||
Measuring range |
0.00 ~ 10.0% |
0 ~ 9999 ppm |
0.0 ~ 20.0% |
|
Resolution |
0.01% |
1 ppm |
0.1% |
|
O2 |
λ |
AFR |
NOX |
|
Measuring range |
0.00 ~ 25.00 % |
0 ~ 2.000 |
0.0~99.0 |
0 ~ 5,000 ppm |
Resolution |
0.01 % |
0.001 |
0.1 |
1ppm |
Display |
4 digit 7segment LED |
|||
Repetition Rate |
Less than 2% FS |
|||
Response time |
Within 10 seconds |
|||
Preheat Time |
Approx. 2~8 minutes |
|||
Flow rate |
4 ~ 6 L/min |
|||
Power |
110V/ 220V±10%, 50/60Hz |
|||
Power consumption |
Approx. 50W |
|||
Operation Temp |
0 ~ 40ºC |
|||
Dimensions |
420 (W) x 298 (D) x 180 (H) mm |
|||
Packing Size |
530 (W) x 400 (D) x 350 (H) mm |
|||
Weight(Net/Gross) |
6.9 kg / 12.5kg |
|||
Standard Accessories (KEG-500) |
Probe, Probe hose, Fuse, Leak test cap, Spare filter, Power cord, RS232, Built-in Printer, Printer paper, Communication cable |
|||
Options |
RPM & OIL temp. meter Built-in printer for KEG-200 |
The person in charge
Choongho KimAddress
119 Gasan digital 1-ro, Geumcheon-gu, Seoul (08589)코엔지
Please enter the text on the left image to prevent automatic input.
0 / 4000